产品展示
PRODUCT DISPLAY
行业资讯您现在的位置:首页 > 行业资讯 > LYBSY-3000 0.05% three-phase power standard source
LYBSY-3000 0.05% three-phase power standard source
  • 发布日期:2026-09-22      浏览次数:4
    • LYBSY-3000  0.05% three-phase power standard source

      LYBSY-3000  0.05% three-phase power standard source

      LYBSY-3000  0.05% three-phase power standard source


      1.IntroductionLYBSY-3000  0.05% three-phase power standard source

      LYBSY-3000 is the use of modern testing, DDS waveform synthesis, high-speed digital processor (DSP), complex programmable logic array (CPLD), large-scale integrated power amplifier, and the design of embedded computer system technology. It is suitable for electric energy meter (optional), AC and DC indicating instrument test and calibration, is ideal equipment for power system the power of product verification and calibration.

      2. Main functions and featuresLYBSY-3000  0.05% three-phase power standard source

      Domestic system, measurement and signal integration in a module, the product of high integration, low failure rate, small volume, light weight, fast response speed, high efficiency, high reliability, strong function, high output power, output standard source.

      Is the original operating system, starting immediately display the test picture, without guidance program, fast response speed, high working efficiency.

      The windows and buttons (with two functions), diversity operation, suitable for different people and habits, simple operation.

      The contents of AC / DC standard source, direct test of various DC indicating instruments.

      The automatic verification energymeter (optional) and indicator indicators.

      The voltage, current, power, phase, frequency, harmonic with superior closed-loop output, setting a place, easy to use software to adjust.

      Thevoltage, current, phase with rich common practical, simple operation, a little place, convenient use and high efficiency.

      Equipped with digital rotary encoder adjustment ,easy to use,simple.

      The outputvoltage, current and power are high precision, high stability standard source,  softwarecalibration.

      Output standard harmonic 2~31 times, can be single or arbitrary superposition of many harmonic output.

      Between the three-phase voltage, three-phase current, between each phase voltage and current can be arbitrary phase shift, so it can simulate all kinds of fault output power.

      Equipped with the three-phase frequency independent phase, frequency conversion.

      Equipped with multiple alarm and protection functions, it can detect the fault automatically and show the fault type and location. It is safe and reliable.

      The preparation of interface and software, open interface protocol, user programmable control instruments.

      Can support domestic similar product operation software.

      3. Main technical indexLYBSY-3000  0.05% three-phase power standard source

      AC analog output

      AC voltage output

      span

      100V 57.735V 380V 220V

      Adjustment range

      0120%

      Adjust fineness

      0.002%

      Accuracy class

      0.05%

      stability

      0.01%/2min

      Distortion

      ≤0.1%Non-capacitive load

      Output load

      30VA/ Channel

      AC current output

      span

      5A2A1A20A

      Adjustment range

      0-120%

      Adjust fineness

      0.002%RG

      accuracy

      0.05%RG

      stability

      0.01%/2min

      Distortion

      ≤0.1%Non-capacitive load

      Output load

      25VA/ Channel

      Output power

      Active power accuracy

      0.05%RG

      Reactive power accuracy

      0.1%RG

      stability

      0.01%/2min

      Phase output

      Adjustment range

      359.99°

      Resolution

      0.01°

      accuracy

      0.05°

      Power factor

      Adjustment range

      -10+1

      Resolution

      0.0001

      accuracy

      0.05%

      frequency

      Adjustment range

      45Hz65Hz

      Resolution

      0.001Hz

      accuracy

      0.002Hz

      Three - phase voltage, current symmetry and phase symmetry

      Voltage, current symmetry

      0.02

      Phase symmetry

      0.05°

      Voltage and current harmonic output

      harmonic order

      231 times

      Harmonic content

      039%

      Harmonic phase

      359.99°adjustable

      accuracy

      0.2%

      DC output (Optional function)

      DC voltage

      Voltage range

      75mV10V100V300V600V

      Output range

      0120%

      accuracy      

      0.05%

      stability

      0.01%/1min

      Ripple content    

      ≤0.5%

      Adjust fineness  

      0.002%RG

      Output load

      10VA

      DC current

      Current range    

      20mA10mA1mA

      Output range

      0120%

      accuracy      

      0.05%

      stability

      0.01%/1min

      Ripple content    

      ≤0.5%

      DC measurement (Optional function)

      DC current measurement

      Measuring range

      0~20mA

      accuracy

      0.05%

      DC voltage measurement

      Measuring range

      0~10V

      accuracy

      0.05%

      Amount of electrical energy pulse (Optional function)

      Pulse output

      Active pulse output

      level 5V±5%Output current 100mA

      Maximum pulse frequency5kHz

      Pulse input

      Active pulse intput

      level 5V±5%input current 1mA

      Maximum pulse frequency5kHz

      Environmental conditions

      Operating temperature

      0℃~40

      Relative humidity

      ≤85%

      Storage conditions

      -30℃~60

      Other

      Working power supply

      AC220V±15%

      volume

      450×440×132mmweight:20kg

      4、Instrument key instructionsLYBSY-3000  0.05% three-phase power standard source

      Key

      instruction

      VRange

      Voltage range switching

      IRange

      Current range switching

      V/Y

      Three  phase four  wire and three  phase three wire

      Switching

      Complete wiring conversionThe display status bar must have a V or Y display.

      SET

      In this series, the key is undefined

      Zero

      All the output down to zero, and cut off the source output, the equivalent of the source off, mainly for wire

      MENU

      menu

      MODE

      In this series, the key is undefined

      Enter

      enter

      XB

      Harmonics keys for setting harmonics.

      U

      Set, display, adjust the voltage

      I

      Set, display, adjust the current

      P

      Set, measure, display, adjust active power

      Q

      Set, measure, display, adjust reactive power

      Φ

      Set, display, adjust the phase

      F

      Set, display, adjust the frequency

      A

      Phase sequence indicator key

      B

      Phase sequence indicator key

      C

      Phase sequence indicator key

      The cursor is shifted to the left; Dc range selection

      The cursor is shifted to the right; Dc range selection

      -

      minus

      1】~【9

      number key

       . 

      Decimal point

      0%】~【120%

      Common voltage and current test point, press this key will also output the percentage at the same time

      0.0L】~【0.0C

      Commonly used capacitive, inductive load test points

      5、Encoder  instructionsLYBSY-3000  0.05% three-phase power standard source

      key

      instruction

      The encoder turns right

      1 The number rises when the cursor is under the digit

      2 DC output range selection

      The encoder turns left

      1 The number drops when the cursor is under the digit

      2 DC output range selection

      Press the encoder down

      And the Enter key [Enter] function the same

      6、Wiring instructions

      AC voltage output

      Wiring method

      Y type wiringthree phase four wireUa Ub Uc Un

      LYBSY-3000  0.05% three-phase power standard source

      V type wiringthree phase three wire) Ua Uc Un

      AC current output

      Wiring method

      Y type wiringthree phase four wireIa Ib Ic

      LYBSY-3000  0.05% three-phase power standard source


      V type wiringthree phase three wire) Ia Ic Ib Wiring short circuit

      DC voltage output

      Wiring method

      Connect the Uo+ and the Rs+ to the + terminal of the test device ;

      Connect the Uo- and the Rs- to the - terminal of the test device ;

      LYBSY-3000  0.05% three-phase power standard source


      DC current output

      Wiring method

      I + terminal connects to the test device + terminal

      I - terminal connects to the test device - terminal

      LYBSY-3000  0.05% three-phase power standard source


      Dc voltage current

      Wiring method

      Green: DC voltage input

      Black: DC voltage, current lowRed: DC current input

      LYBSY-3000  0.05% three-phase power standard source


      7、Instrument interface operation instructions

      7.1Menu selection interface

      At any interface, press the [MENU] key pop-up menu to select the interface:

      LYBSY-3000  0.05% three-phase power standard source

      7.2AC output interface

      After power on, enter the standard output interface, as follows:



      V

      0.000

      0.000

      0.000

      DC

      0.001

      A

      0.000

      0.000

      0.000

      0.001

      φU

      0.000

      0.000

      0.000


      φI

      0.000

      0.000

      0.000

      50.000Hz

      W

      0.000

      0.000

      0.000

      0.000

      Vr

      0.000

      0.000

      0.000

      0.000

      VA

      0.000

      0.000

      0.000

      0.000

      PF

      0.000

      0.000

      0.000

      0.000


      100V   5A   Type YNo harmonicOpen loop

      AC output interface operating instructions:

      Gear selection of voltage and current

      pressVRange

      Switching voltage limit

      pressIRange

      Switching current limit

      Quick output of voltage

      pressdigit】【U】【Enter

      Simultaneous rise of threephase voltage

      pressdigit】【U】【A】【Enter

      rise only Ua=digit

      pressdigit】【U】【B】【Enter

      rise only Ub=digit

      pressdigit】【U】【C】【Enter

      rise only Uc=digit

      Quick output of current

      pressdigit】【I】【Enter

      Simultaneousrise of  threephase current

      pressdigit】【I】【A】【Enter

      rise only Ia=digit

      pressdigit】【I】【B】【Enter

      rise only Ib=digit

      pressdigit】【I】【C】【Enter

      rise only Ic=digit

      Voltage and current angle setting

      pressdigit】【Φ】【Enter

      Set the threephase power factor angle =digit

      Output frequency setting

      pressdigit】【F】【Enter

      Set the standard output frequency =digit

      Coarse adjustment and finetuning of various parameters

      pressU】【EnterEnter the display areaU=×××.××× V, Rotate the digital encoder, which will adjust the digit size of the cursor.Press 】【 key to move the cursor position, will realize the parameter of the coarse and fine tuning.

      pressU】【Enter

      Adjust the amplitude of the three-phase voltage simultaneously

      pressU】【A】【Enter

      Adjust the amplitude of A phase voltage

      按【U】【B】【Enter

      Adjust the amplitude of B phase voltage

      pressU】【C】【Enter

      Adjust the amplitude of C phase voltage

      pressI】【A】【Enter

      Adjust the amplitude of A phase current

      pressI】【B】【Enter

      Adjust the amplitude of B phase current

      pressI】【C】【Enter

      Adjust the amplitude of C phase current

      pressΦ】【Enter

      Adjust voltage and current angle

      pressF】【Enter

      Adjust output frequency

      Turn off source output

      pressZero

      Turn off source output

      Three phase four wire and threephase three wire conversion

      pressV/Y

      Three phase four wire and threephase three wire switching

      switch interface

      pressMENU

      Menu selection interface






      7.3DC output interface

                                                                              0.0000V

      gear

      DC voltage 600V

      Gear selection


      status

      DC source is open, DC voltage output

      DC output interface operating instructions

      DC gear selection

      PressVRange

      Use the [←] [→] key to select the voltage range

      PressIRange

      Use   key to select the current range

      DC voltage output

      Pressdigit】【U】【Enter

      output voltageU =digit

      Press0%】~【120%Common voltage test point

      The percentage voltage of the output gear

      PressU】【Enter

      Adjust voltage value by knob

      DC current output

      Pressdigit】【I】【Enter

      Output current I =digit

      Press0%】~【120%Common current test points

      The percentage current of the output gear

      PressI】【Enter

      Adjust current value by knob

      Turn off DC source

      PressZero

      DC output wiring

      DC current wiring: the connection cable to the front panel, DC current output terminals, red terminal for the positive,

      Black terminal is negative.

      DC voltage wiring: DC voltage output using four-wire output, where UO +, UO- for the outputterminal.

      7.4Harmonic display interface

      Order

      UA[%]

      10+

      20+

      IA[%]

      10+

      20+

      Total

      0.000

      THDU

      0.000

      0.000

      THDI

      0.000

      1

      100.00

      0.000

      0.000

      100.00

      0.000

      0.000

      2

      0.000

      0.000

      0.000

      0.000

      0.000

      0.000

      3

      0.000

      0.000

      0.000

      0.000

      0.000

      0.000

      4

      0.000

      0.000

      0.000

      0.000

      0.000

      0.000

      5

      0.000

      0.000

      0.000

      0.000

      0.000

      0.000

      6

      0.000

      0.000

      0.000

      0.000

      0.000

      0.000

      7

      0.000

      0.000

      0.000

      0.000

      0.000

      0.000

      8

      0.000

      0.000

      0.000

      0.000

      0.000

      0.000

      9

      0.000

      0.000

      0.000

      0.000

      0.000

      0.000

      10

      0.000

      0.000

      0.000

      0.000

      0.000

      0.000

      A phase

      F content

      P add

      Q delete











      Harmonic display operation instructions

      ABC phase switch

      PressA】【B】【C

      Switch the current display

      Add \ remove harmonics

      PressP】【Q

      Enter interface

      7.5Vector display interface


      UA

      0.00

      UB

      0.00

      UC

      0.00

      IA

      0.00

      IB

      0.00

      IC

      0.00

      a

      0.00

      b

      0.00

      c

      0.00

      F customary law

      P angle

      Q 0~360





      Vector display operation instructions

      UA.UB.UC

      Three phase voltage Angle

      IA.IB.IC

      Three phase current Angle

      a.b.c

      The angle between three phase voltage and current

      7.6electric energy calibration interface

      Electric energy error


      running

      Measured electrical energy


      Active power

      Voltage

      0.000

      0.000

      0.000

      constant

      0.0

      Current

      0.000

      0.000

      0.000

      Number of turns

      0

      Voltage phase

      0.000

      0.000

      0.000

      Low frequency output

      Current phase

      0.000

      0.000

      0.000

      50.000Hz

      Active power

      0.000

      0.000

      0.000

      0.000

      Reactive power

      0.000

      0.000

      0.000

      0.000

      Apparent power

      0.000

      0.000

      0.000

      0.000

      Power factor

      0.000

      0.000

      0.000

      0.000

      State

      100V   5A   Type YNo harmonicOpen loop








      Electric energy calibration method:

      Press 【→】 key, the cursor enters the editing state,then press the number key on the panel.Press 【→】 key, the cursor enters the next edit box,When the parameters are all set up,press [Enter] to confirm and start the verification.

      Active energy calibration and reactive energy calibration, switching method:

      Press 【→】 to the active energy, press 【Enter】 key to switch active or reactive.

      Press 【→】 to the constant, set the constant, press 【Enter】 to determine.Press 【→】 to the number of turns, set the number of turns, press 【Enter】 to determine.

      Press 【→】 to stop the verification, press 【Enter】 to start the calibration,

      Constant setting range

      set range(1A-18000;2A-9000;5A-3600;20A-900).

      Number of turns setting range

      set range (1---9999999)Generally set about 5 laps, refresh soon, the number of laps set bigger.

      Pulse port definition


      LYBSY-3000  0.05% three-phase power standard source

      1 pin :  signal  (green)

      3 pin :  5V    (red)

      5 pin :  ground    (black)


      Wiring method of active electric energy meter


      LYBSY-3000  0.05% three-phase power standard source

      Wiring method of passive electric energy meter


      LYBSY-3000  0.05% three-phase power standard source

      7.7Parameter calibration interface

      This interface is for calibration of instrument parameters. In order to ensure the accuracy of the instrument, this interface is not open to the user.

      8、Attention

      The instrument must have a good grounding in use

      Check the temperature of 23 + 1 degrees.

      To ensure the accuracy of the instrument, please preheat 30 minutes before use.

      Attention should be paid to the proper limits of the objects to be measured.

      instrument terminal output as standard source, the terminal can not access any other power supply.

      tandard power output, you must first select the output voltage and phase, power loss

      Out of the maximum 120% of the theoretical value.

      In this equipment and other equipment shall disconnect all power devices connected before communication, however electrical connections cause damage to the equipment.

      When DC output 5A 25A, please raise the current to 100%, preheat five to ten minutes.

    联系方式
    • 电话

      13801861238

    在线客服